LINUXOR.SK ... open source notes ...

Linux Storage - MDS flogi and fcns databases

category: solutionz · date: 2013-12-31 · updated: 2026-10-03 · author: LALA

Linux Storage Solution · Config document · referenced from FC aliases, zones and zonesets and SCSI addressing and FC names

The two state listings that show who is logged into the fabric of FCSwitch1: the fabric login (flogi) database with one row per logged-in port, and the name server (fcns) database with the same ports grouped by VSAN, each marked as a SCSI initiator or target. They were taken after the base configuration and before the aliases were written, and every port WWN in the aliases and the port-security database comes from here.

ItemValue
SwitchFCSwitch1, Cisco MDS 9124e, NX-OS 5.2(8)
Commandssh flogi database, sh fcns database, exec mode, as admin
Logged in7 ports: 5 blade HBA ports on bay1 to bay5, 2 3PAR ports on ext1 and ext2
VSANs11 with 4 entries, 12 with 3 entries
Second switchNo flogi or fcns listing of SW2 is in the notes

The listing

The fabric login database, taken at the exec prompt of FCSwitch1. One row per interface: the VSAN the port is in, the FCID the switch assigned at login, and the port and node WWN the device presented.

bash
$ sh flogi database
output 12 lines
--------------------------------------------------------------------------------
INTERFACE        VSAN    FCID           PORT NAME               NODE NAME
--------------------------------------------------------------------------------
bay1             11    0x2a0000  50:01:43:80:12:34:56:c0 50:01:43:80:12:34:56:c1
bay2             11    0x2a0100  50:01:43:80:12:34:56:d4 50:01:43:80:12:34:56:d5
bay3             12    0x660000  50:01:43:80:12:34:57:90 50:01:43:80:12:34:57:91
bay4             12    0x660200  50:01:43:80:12:34:57:92 50:01:43:80:12:34:57:93
bay5             11    0x2a0200  50:01:43:80:12:34:40:2c 50:01:43:80:12:34:40:2d
ext1             11    0x2a0300  21:12:00:02:ac:00:ab:cd 2f:f7:00:02:ac:00:ab:cd
ext2             12    0x660300  21:11:00:02:ac:00:ab:cd 2f:f7:00:02:ac:00:ab:cd

Total number of flogi = 7.

The name server database, same prompt. It adds what the login database lacks: the vendor the switch derives from the WWN and the FC-4 feature, which says whether the port is a SCSI initiator (a host HBA) or a SCSI target (a storage port).

bash
$ sh fcns database
output 20 lines
VSAN 11:
--------------------------------------------------------------------------
FCID        TYPE  PWWN                    (VENDOR)        FC4-TYPE:FEATURE
--------------------------------------------------------------------------
0x2a0000    N     50:01:43:80:12:34:56:c0 (HP)            scsi-fcp:init
0x2a0100    N     50:01:43:80:12:34:56:d4 (HP)            scsi-fcp:init
0x2a0200    N     50:01:43:80:12:34:40:2c (HP)            scsi-fcp:init
0x2a0300    N     21:12:00:02:ac:00:ab:cd                 scsi-fcp:target

Total number of entries = 4

VSAN 12:
--------------------------------------------------------------------------
FCID        TYPE  PWWN                    (VENDOR)        FC4-TYPE:FEATURE
--------------------------------------------------------------------------
0x660000    N     50:01:43:80:12:34:57:90 (HP)            scsi-fcp:init
0x660200    N     50:01:43:80:12:34:57:92 (HP)            scsi-fcp:init
0x660300    N     21:11:00:02:ac:00:ab:cd                 scsi-fcp:target

Total number of entries = 3

The columns

ColumnMeaning
INTERFACEthe switch port the device is cabled to; bayN is the internal link to blade slot N, extN an external SFP port
VSANthe VSAN the interface was assigned to in the base configuration
FCIDthe fabric address the switch gave the port at login (24 bits wide, as I understand it); the first byte differs between the two VSANs (0x2a in VSAN 11, 0x66 in VSAN 12)
PORT NAME, PWWNthe port WWN of the device, the identity used in aliases, zones and port security
NODE NAMEthe node WWN; both 3PAR ports share one node name, each HBA port has its own
TYPEN for an N_Port, an end device
(VENDOR)the switch's name for the OUI in the WWN; HP for 50:01:43:80, nothing for the 3PAR's 00:02:ac
FC4-TYPE:FEATUREscsi-fcp:init for an initiator, scsi-fcp:target for a target

Who is who

The listings carry no host names. Joining them with the cabling schema and the aliases written afterwards:

InterfaceVSANFCIDpwwnRoleDevice
bay1110x2a000050:01:43:80:12:34:56:c0initiatorHV01, first HBA port (host1 on Linux)
bay2110x2a010050:01:43:80:12:34:56:d4initiatorHV02
bay5110x2a020050:01:43:80:12:34:40:2cinitiatorMGMT01
ext1110x2a030021:12:00:02:ac:00:ab:cdtargetStorage1, 3PAR port 0:1:1, alias Storage1-C0P0
bay3120x66000050:01:43:80:12:34:57:90initiatorHV03
bay4120x66020050:01:43:80:12:34:57:92initiatorHV04
ext2120x66030021:11:00:02:ac:00:ab:cdtargetStorage1, 3PAR port 0:1:2, alias Storage1-C0P1

The bay1 row is the one that can be checked from the other side: on HV01, port_name of host1 is 0x50014380123456c0 and its port_id is 0x2a0000, and the remote port it sees has port_id 0x2a0300 and port_name 0x21120002ac00abcd, the ext1 row. The notes list no such check for the other blades. The 3PAR port numbers in the Device column come from the schema, not from the switch; the switch only knows the WWNs, and see SCSI addressing and FC names for why the port names say otherwise.

Checked against Cisco MDS NX-OS 9.4(5a)

As builtToday
show flogi database with the columns INTERFACE VSAN FCID PORT NAME NODE NAME and the line "Total number of flogi = N."Unchanged
show fcns database with the columns FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATUREUnchanged
Interfaces bayN and extNBlade-switch names; current guides show fcX/Y
NX-OS 5.2(8) on an MDS 9124eThe MDS 9124 reached its last date of support on 31 January 2019; 5.2(8i) is its last release

The 9.x fabric guide also notes that FC aliases never appear in these two listings or in show zoneset active; they travel only with the full zone database. That is why the "Who is who" table above had to be built by hand.

← solutionz