NetApp - ONTAP disk ownership, aggregates and volumes as built

category: solutionz · date: 2019-12-31 · updated: 2026-10-02 · author: LALA

NetApp Solution · Config document · referenced from Storage design

noteThis is a listing of state, not a command set. The notes on disk assignment contain no storage disk assign, storage aggregate create or volume create command, and none are invented here. The only commands in the notes are the ones that display the state; they head the blocks below.

The storage configuration of one cluster as it was recorded: shelves, disk ownership by node and pool, aggregates with their plexes, volumes, and the policies on them. It is the result of the disk assignment and the aggregate layout, without the steps that led there.

ItemValue
Shown hereCluster DC1-A-XNAS001, datacenter A of site 1
Also applies toDC1-B-XNAS001; see the differences below
SourcesThe as-built report produced with NetAppDocs, the disk layout spreadsheet of the design, and storage shelf show from the notes of September 2017
ColumnsThose of the sources, arranged under the ONTAP command that shows the object; not the exact output of the commands
ONTAP version at the time9.1P11
State of the SVMsFour data SVMs; the volumes of the two SVMs added in 2019 are not in the report

The file

ini
# --- storage shelf show ------------------------------------------------------
# Output of September 2017. Stack numbers are assigned by the cluster and
# were different in later listings; shelf IDs are fixed.
# Shelf  ID  Model     Module  Status  Datacenter    Disks
1.30     30  DS224-12  IOM12   Normal  A             24
1.31     31  DS224-12  IOM12   Normal  A             16
2.10     10  DS224-12  IOM12   Normal  A             24
2.11     11  DS224-12  IOM12   Normal  A             24
3.20     20  DS224-12  IOM12   Normal  A             24
3.21     21  DS224-12  IOM12   Normal  A             24
4.70     70  DS224-12  IOM12   Normal  B             24
4.71     71  DS224-12  IOM12   Normal  B             16
5.60     60  DS224-12  IOM12   Normal  B             24
5.61     61  DS224-12  IOM12   Normal  B             24
6.50     50  DS224-12  IOM12   Normal  B             24
6.51     51  DS224-12  IOM12   Normal  B             24

# --- storage disk show -ownership, summed up ---------------------------------
# Disk type 1.2TB_SAS_10k, 1.09 TB usable. Pool0 is the datacenter of the
# owning node, Pool1 the other one.
# Owner          Disks  In aggregates  Spare  Pool0 (shelves)       Pool1 (shelves)
DC1-A-ANAS001    130    58             72     10 to 30 and 5 of 31  50 to 70 and 5 of 71
DC1-A-ANAS002    120    14             106    10 to 30              50 to 70
DC1-B-ANAS001    16     14             2      71                    31
DC1-B-ANAS002    6      4              2      71                    31

# --- storage aggregate show --------------------------------------------------
# All aggregates: online, mirrored, normal.
# Aggregate            Node           RAID     Disks  RG size  HA policy  Root  Size
DC1_A_ANAS001_data1    DC1-A-ANAS001  raid_dp  54     16       sfo        no    21.42 TB
DC1_A_ANAS001_root     DC1-A-ANAS001  raid4    4      8        cfo        yes   953.80 GB
DC1_A_ANAS002_data1    DC1-A-ANAS002  raid_dp  10     16       sfo        no    2.79 TB
DC1_A_ANAS002_root     DC1-A-ANAS002  raid4    4      8        cfo        yes   953.80 GB

# --- storage aggregate plex show ---------------------------------------------
# Plex names from the disk layout spreadsheet; disk counts are half of the
# aggregate.
# Aggregate            Plex   Pool  Datacenter    Disks
DC1_A_ANAS001_data1    plex0  0     A             27
DC1_A_ANAS001_data1    plex1  1     B             27
DC1_A_ANAS001_root     plex0  0     A             2
DC1_A_ANAS001_root     plex4  1     B             2
DC1_A_ANAS002_data1    plex0  0     A             5
DC1_A_ANAS002_data1    plex1  1     B             5
DC1_A_ANAS002_root     plex0  0     A             2
DC1_A_ANAS002_root     plex4  1     B             2

# --- volume show -------------------------------------------------------------
# <ID> stands for the identifier MetroCluster puts into the names of its
# metadata volumes.
# Vserver         Volume               Aggregate            Size       Snapshot policy  Style
DC1-A-ANAS001     vol0                 DC1_A_ANAS001_root   902.54 GB  -                -
DC1-A-ANAS002     vol0                 DC1_A_ANAS002_root   902.54 GB  -                -
DC1-A-XNAS001     MDV_CRS_<ID>_A       DC1_A_ANAS001_data1  10.00 GB   none             unix
DC1-A-XNAS001     MDV_CRS_<ID>_B       DC1_A_ANAS002_data1  10.00 GB   none             unix
DC1-S-VCVSM001    DC1_S_VCVSM001_root  DC1_A_ANAS002_data1  1.00 GB    default          unix
DC1-S-VCVSM001    DC1_S_VCVSM001_data  DC1_A_ANAS002_data1  100.00 GB  default          unix
DC1-S-VCVSM002    DC1_S_VCVSM002_root  DC1_A_ANAS001_data1  1.00 GB    default          unix
DC1-S-VCVSM002    DC1_S_VCVSM002_data  DC1_A_ANAS001_data1  10.10 TB   none             unix
DC1-S-VCVSM003    DC1_S_VCVSM003_root  DC1_A_ANAS001_data1  1.00 GB    default          ntfs
DC1-S-VCVSM003    DC1_S_VCVSM003_data  DC1_A_ANAS001_data1  100.00 GB  default          ntfs

# --- volume show -fields space-guarantee, autosize, efficiency ---------------
# The same on every volume above.
space guarantee        = volume
deduplication          = not enabled
compression            = not enabled
autosize               = disabled
try first when full    = volume_grow
snapshot autodelete    = disabled
autodelete trigger     = volume
target free space      = 20%

# --- volume snapshot policy show ---------------------------------------------
# Policy          Enabled  Schedules: copies kept
default           true     hourly: 6, daily: 2, weekly: 2
default-1weekly   true     hourly: 6, daily: 2, weekly: 1
none              false    -

# --- job schedule show, the schedules the policies use -----------------------
hourly  = every hour at minute 5
daily   = every day at 0:10
weekly  = Sunday at 0:15

# --- volume efficiency policy show -------------------------------------------
# Present in every data SVM, used by no volume.
# Policy       Enabled  Schedule  QoS policy
default        true     daily     best_effort
inline-only    -        -         -

What changes on cluster B

ObjectDC1-A-XNAS001DC1-B-XNAS001
Shelf namesAs aboveThe same shelves as 1.50, 1.51, 2.60, 2.61, 3.70, 3.71, 4.10, 4.11, 5.30, 5.31, 8.20, 8.21
Data aggregatesOne on each node, 54 and 10 disksOne only: DC1_B_ANAS001_data1, raid_dp, 10 disks, 2.79 TB
Root aggregatesDC1_A_ANAS001_root, DC1_A_ANAS002_rootDC1_B_ANAS001_root, DC1_B_ANAS002_root, same size and RAID type
Plexesplex0 in datacenter A; mirror plex1 or plex4 in Bplex0 in datacenter B; mirror plex1 for the data aggregate and plex4 for the root aggregates in A
MDV_CRS volumesOne on each data aggregateBoth on DC1_B_ANAS001_data1
SVM volumesRoot and data volumes of three SVMsDC1_S_VCVSM004_root only, 1 GB, security style ntfs, snapshot policy default
Snapshot policiesdefault, default-1weekly, noneThe same three; on each cluster the policies of the mirrored SVMs of the partner also appear, with the suffix -DR

What changed later

ObjectAs-built report, 2018Final design, 2019
DC1_A_ANAS001_data154 disks64 disks
Volumes on itThose aboveAlso DC1_S_VCVSM002_data2, and root and data volumes of DC1-S-VCVSM005 and DC1-S-VCVSM006
Site 2, DC2_A_ANAS001_data1Not built yet38 disks
Aggregate namesDC1_<datacenter>_<node>_data1 and _rootUnchanged. In September 2017 they were still data_DC1_A_ANAS001, root_DC1_A_ANAS001 and so on

The commands with which the state was looked at are in Storage design.

Checked against ONTAP 9.19.1

As builtToday
Pool 0 local, pool 1 remoteUnchanged for MetroCluster FC. Disks are assigned to a pool with storage disk assign, which keeps its -pool and -owner parameters, or in maintenance mode with disk assign -shelf and -p 0 or -p 1. NetApp states that new MetroCluster systems are shipped with the disk assignment done
Mirrored aggregatesstorage aggregate create with -mirror true and storage aggregate mirror are unchanged
Whole-disk root aggregatesRoot-data partitioning is still listed as not supported for fabric-attached MetroCluster; it is supported for MetroCluster IP from ONTAP 9.4
storage disk show -ownership, storage disk option show, storage aggregate show -diskAll still in the command reference
DS224C shelves with IOM12 modulesNot among the shelves whose support was discontinued
FAS8200Support discontinued from ONTAP 9.17.1; the last release for it is 9.16.1

The first row explains part of what the notes lack. A MetroCluster arrives with its disks assigned, so there may never have been a full set of assignment commands to keep; what was done by hand here was the later rearrangement of the short shelves, and that is the part that is missing.